Biodata |
|
Name of the Candidate | : | [Private] |
Name of the Post Applied | : | HVAC Design Engineer |
Job related skills / software | : | Revit MEP, Autocad, HAP, ESP Calculation, McQuayDuctsizer, Pipe Sizer, Creo parametric (Pro/E) |
Category | : | Design Engineering |
Sub Category | : | HVAC Designer / Design Engineer |
Years of Experience | : | 1 years |
State | : | Maharashtra |
Gender | : | Male |
Salary Expected per Month(Rs) | : | 20,000 to 25,000 |
Highest Qualification attained | : | M.Tech. : Master of Technology |
Major / Specialization | : | Heat Power |
Email Id | : | [Private] |
|
Are you looking for job now? | : | Yes |
Can the recruiter contact you? | : | Yes |
Sponsored Links:
|
Resume Format / CV Sample Template / Example / Model : |
|
MIRZA ATIQUR RAHMAN
Email :atiqmirza786 AT gmail.com
CAREER OBJECTIVE :
To be associated with a company that offers an all-round development for personal and professional growth in line with company’s goals and vision.
EDUCATIONAL QUALIFICATION :
** Master of Technology in Heat Power Engineering from GH Raisoni college of Engineering and Management Pune with CGPA of 9.83 in 2020.
** Bachelor of Engineering in Mechanical Engineering from BN College of Engineering Pusad with CGPA of 9.56 in 2016.
** Diploma in Mechanical Engineering from Dr NP Hirani Polytechnic Pusad with 86.93% in 2013.
** SSC from S.U.Urdu High School Pusad with 91.45% in 2010.
EXPERIENCES :
1 Year Experience as HVAC Design Engineer in Dhanush Engineering Services Hyderabad for various applications such as High Residential, Commercial building and Hotel Projects.
PROJECTS HANDLED :
Project Name : Sheraton Hotel Service Rooms, Hyderabad
Client :Sheraton Hotels and Resorts
Designation : HVAC Engineer
This project has 64 Service Rooms, 3 basements, lift well and stair well pressurization. This project is served by water cooled chillers and Fan Coil Units (FCU) in service rooms. Basement ventilation is done by using supply and exhaust axial fans with ducting system.
Project Name : DST Workstation Hyderabad
Client : DST Worldwide Services
Designation : HVAC Engineer
Role and Responsibilities :
** Heat Load Calculations using E20 Sheets.
** Duct sizing using McQuay Duct Sizer.
** Drafting using AutoCAD 2016 and Revit 2017.
** ESP Calculations using Elite Duct Size 6.01.179.
** Air Handling Machine selection based on ASHRAE standards.
** Chilled water pipe sizing using McQuay Pipe Sizer.
** 3 months worked as an intern in Cell Propulsion Bangalore.
Role and Responsibilities :
** Study related to Modeling and design of heat sink.
** Pressure loss calculations inside an automobile radiator piping system.
** Temperature drop calculations inside an automobile radiator for coolant as well as air.
** Preparing report on Vendors for various equipments required for our project.
** Designing, modeling and CFD Simulation of battery pack system in electric vehicle using Creo5.0 and FEMAP.
SKILLS :
Software Known : Revit MEP , Auto Cad, HVAC, and Creo parametric (Pro/E)
** Strong fundamentals on MEP Design and knowledge on Revit MEP.
** Prepared working drawings plan, section & elevations for small Residential projects.
** Prepared standard drawings for types of buildings like Commercial, Residential & Hospital.
** Revit Model developing from various inputs like Cad drawing, PDF& 3D scanned point cloud data point formats.
** Collaborating and Coordination of Revit files.(Basic knowledge about coordinating).
** Linking/importing the CAD file into Revit
** Compatible to work with drafting software, Microsoft Office.
ABOUT PROJECTS :
M Tech Project : Thermal Modeling and Design on Smart phones with Heat Pipe Cooling Technique.
In this research work,I have developed a model of bended heat pipe and performed the simulation for that bended heat pipe and compared its performance with the straight heat pipe that we use in Mobile Phones.
With results, it is concluded that bended heat pipe is more thermally efficient compared to straight one. Here modeling is done by using Catia V5 and analysis on Ansys Fluent.
BE Project : Experimental Investigation of Thermal Performance of Solar Air Heater with Surface Roughness
In this research work, a new technique of heat transfer enhancement is proposed, which contains an artificial roughness in the form of multi arc shape ribs with gap on the inner side surface of the absorber plate. The artificial roughness on the absorber plates is of different pitch ratios. Its performance is compared with straight absorber plate.
ACHIEVEMENTS :
** Qualified GATE 19 with 49.85 marks with AIR of 10515.
** Qualified GATE 18 with 52.35 marks with AIR of 11360.
** Qualified GATE 17 with 37.4 marks with AIR of 21512.
** 2nd merit in Sant Gadge Baba Amravati University.
** Published paper in five International and National Level Paper Presentation Conferences.
** Vice President in SRC (Students Representative Council) for session 2014.
HOBBIES :
Playing Cricket, Active on twitter, Reading news etc.
PLACE:
DATE:
|
|
Notes |
1. This is an online resume, managed by the candidate.
2. Create your online resume here.
3. If candidate allows, recruiters can contact the candidate directly.
4. Personal and contact details can be kept private optionally by the candidate.
5. Create a link to this online resume where ever you want in the web.
|
|