Name of the Candidate:[Private]
Name of the Post Applied:Testing & Commissioning Engineer
Job related skills / software:Installation of panel, transformer and cable laying & termination, Testing and commissioning of all Electrical equipment, Inspection of control and relay panel, preparation of Test Report for power plant.
Category:Site / Construction
Sub Category:Installation Engineer / Commissioning Engineer
Years of Experience:5 years
State:Gujarat
Gender:Male
Salary Expected per Month(Rs):50,000 to 60,000
Highest Qualification attained:B.E. / BE : Bachelor of Engineering
Major / Specialization:Electrical
Email Id:[Private]
 
Are you looking for job now?:Yes
Can the recruiter contact you?:Yes
Sponsored Links:

Resume Format / CV Sample Template / Example / Model :

    

Name  : Darshak V. Sonagra
Education  : B.E. Electrical
Experience  : 4 Years 10 Months Project Field
Mobile  : 8511104528
Email  : sonagra111darshak AT gmail.com

Statement of Purpose :
Working with an organization, which will permit me to use and contribute my skill and also to enhance my knowledge and contribute towards its growth by committed and high quality work.

Job Responsibility  :
** Installation of panel, transformer and cable laying & termination.
** Testing and commissioning of all Electrical equipment from 415 volts to 6.6 KV System.
** Inspection of control and relay panel, preparation of Test Report for power plant.
** Testing and commissioning of control & relay panel for Generator, Transformer and Bus Coupler, Bus-Transfer, and Line feeder.(LT & HT)
** Configuration as per schematic diagram & Testing of Protective Relays for various needs.
** Knowledge of Transformer protection, Transformer Differential Protection, Bus Bar Differential protection, Motor protection, and synchronizing scheme.
** Testing of CT, P.T. and Circuit breaker, Numerical Relays, Auxiliary Relays and Power Transformer.
** Trouble shooting of all Electrical circuits, control and protection circuits.
** Planning of Electrical work as per Design provided.
** Good Co-ordination & interaction with higher authorities, client & sub-contractor and work related other department.
** Site inspection and other addition works for job related.
** Good knowledge of Electrical Drawings,
** Planning of Projects, Erection, Maintenance & Commissioning.
** Maintain day to day work and progress report.
** Installation of CT, PT, CVT, Isolator, Circuit Breaker, Relay & Transformer in switchyard.
** Testing & commissioning of CT, PT, CVT, Isolator, Breaker, Relay & transformer in switchyard.
** Testing & commissioning of PCC, MCC panels.
** Testing & commissioning of Transformers.
** Knowledge of CT, PT, Circuit Breaker, MCCB, Busbar, Busduct and Earth Pit Testing.
** Knowledge of L&T, Siemens, C&S, Alstom, MiCOM, SEL, ABB make numerical relays & Auxiliary relay.
** Testing of various Motors.
** Knowledge of changeover & synchronizing scheme.
** Configuration as per schematic diagram of Protective Relays for various needs.
** Testing of Cables up to 220 KV.
** Preparation of Test Report for Various Equipment.
** Testing of 63A, 125A, 250A, 400A, 800A Power DB’s.

Project-1  : Thermal power plant (Cli, Sikka, Jamnagar (Unit 3 & 4)
Project–2 : 220 KV switchyard in Reliance Captive Power Plant.
Project-3 : Substation Testing & commissioning in Various site in Reliance JMD, HMD, SMD.
Project-4 : GIS (33 KV) in Reliance JMD.
Project-5 : Testing of PDB.
Project-6 : Testing of HT Panels at ESSAR.
Project-7 : Testing Work at 66 KV Switchyard & 6.6 KV System at HMEL.
Project-8 : Testing work at 33 KV System at RSPL, Dwarka.

Professional Experience  :
Present Job  : EXCEL TECHNICAL SERVICES PRIVATE LIMITED
Position Held  : Commissioning Engineer
Job Duration  : June-2013 to Till Date.
Present Site  : HMEL,MITTAL ENERGY, BHATHINDA, PUNJAB

Vocational Training : Thermal power plant, Sikka
Work Duration  : JUNE-2012 TO JULY-2012

Acadamic Project  :
 Title : Automatic Power Factor Correction by Microcontroller 8052.
Duration : Jan 2013 – May 2013 (in 8th SEM.)

Title : Energy Audit of Our College Premises.
Duration : July 2012 – Nov 2012 (in 7th SEM.)

Academic Record  :
Bachelor Of Engineering In Electrical Engineering
University  : Gujarat Technological University-Gujarat.
Passing year  : May-2013
Percentage  : 7.66 CGPA

H.S.C.


:
University  : Gujarat Secondary Education board Gandhinagar
Passing year  : May-2009
Percentage  : 55.80 %

S.S.C :
University  : Gujarat Secondary Education board Gandhinagar
Passing year  : April-2007
Percentage  : 77.54 %

Personal Details :
Name  : Darshak Sonagra
Father’s Name  : Vijaybhai Mohanlal Sonagra
Date of Birth  : 30th April 1992
Place of Birth  : Jamnagar
State  : Gujarat
Gender  : Male
Marital Status  : Married
Permanent Address  : Patel Colony, Vikas Gruh Road, Sudama Street,”Satyam” Apartment, Jamnagar - 361008.

Hobbies :
** Interested to Learn New things.
** Playing Chess & Cricket.

Computer Skills :
** Microsoft Office
** Internet Work
** Matlab
** Photoshop

Declaration:
I hereby asseverate that all the details mentioned above are true and authentic to the best of my knowledge.

Date :
Place :

Notes

1. This is an online resume, managed by the candidate.
2. Create your online resume here.
3. If candidate allows, recruiters can contact the candidate directly.
4. Personal and contact details can be kept private optionally by the candidate.
5. Create a link to this online resume where ever you want in the web.